Welcome to The International Hypnosis Research Institute Web site. Our intention is to support and promote the further worldwide integration of comprehensive evidence-based research and clinical hypnotherapy with mainstream mental health, medicine, and coaching. We do so by disseminating, supporting, and conducting research, providing professional level education, advocating increased level of practitioner competency, and supporting the viability and success of clinical practitioners. Although currently over 80% of our membership is comprised of mental health practitioners, we fully recognize the role, support, involvement, and needs of those in the medical and coaching fields. This site is not intended as a source of medical or psychological advice. Tim Brunson, PhD

A computer aided method for closed reduction of diaphyseal tibial fracture using projection images.



A computer aided method for closed tibial shaft fracture reduction based on measurements of 12 projection parameters (6 angulations and 6 translations) from an anteroposterior radiograph, a lateral radiograph, and a transverse projection photograph is examined. The development, validation and reliability of the computer aided method are presented. A custom-made unilateral external fixation device consisting of 7 calibrated one-degree-of-freedom joints was employed to execute the reduction. Five tibial fracture phantoms with initial deformities that covered a wide range of misalignments were tested. The mean (standard deviation) resultant rotational and translational errors after the reduction were 3.32 degrees (0.96 degrees ) and 1.65 (0.86) mm, respectively, which indicates good reduction accuracy. Three indFrelendent raters made the measurements of the projection parameters to test inter-rater reliability. The intra-class correlation coefficients were found to range between 0.935 and 1, indicating good reliability. Since ideal patient positioning for AP, lateral and transverse image acquisition is not easily attainable, the effect of patient positioning errors on the measurement of projection parameters was explored using a tibial phantom. The preliminary results revealed that 10 degrees deviations in positioning do not greatly affect the measurement of AP and lateral angulation parameters (<1.7 degrees ). However, a 10 degrees positioning error about the long bone axis may result in a change of as much as 10.7 degrees in the measurements of transverse projection angulation parameters. In addition, a 10 degrees positioning error about an arbitrary anatomical axis may result in translational projection parameter changes of up to 6.8 mm. For these reasons, a previously validated method that allows for accurate positioning of the tibia about its long axis and a two-step reduction strategy to achieve the best possible deformity reduction are proposed. Procedures to facilitate reliable measurement of tibial torsion are also discussed. It appears that the projection-based reduction method exposes the patient to less radiation and allows for simple, quick and accurate reductions, making it an attractive choice for acute clinical applications.

Comput Aided Surg. 2009 Jun 10:1-13. Koo TK Assistant Professor, Papuga MO. Foot Levelers Biomechanics Research Laboratory, Department of Research, New York Chiropractic College, Seneca Falls, New York.

TrackBacks
There are no trackbacks for this entry.

Trackback URL for this entry:
https://www.hypnosisresearchinstitute.org/trackback.cfm?379BC5B4-C09F-2A3B-F628D7E1CBB99422

Comments
© 2000 - 2025The International Hypnosis Research Institute, All Rights Reserved.

Contact