Tim Brunson DCH

Welcome to The International Hypnosis Research Institute Web site. Our intention is to provide quality information to clinicians and the general public concerning hypnosis, hypnotherapy, and other mind/body modalities. We intend to expand our coverage to include such topics as Neuro-Linguistic Programming (NLP), energy psychology and medicine, and other related topics. While our intention is to provide quality information derived from valid sources, including peer reviewed literature concerning significant research, this site is not presented as a source of medical or psychological advice. Clinicians wishing to expand their scope of practice or protocols based upon presented information should perform due diligence prior to use. It is our sincere hope to stimulate interest in these topics and to contribute to the evolution of the science of hypnosis. -- Tim Brunson, PhD

Multiecho coarse voxel acquisition for neurofeedback fMRI.

"Real-time" functional magnetic resonance imaging is starting to be used in neurofeedback applications, enabling individuals to regulate their brain activity for therapeutic purposes. These applications use two-dimensional multislice echo planar or spiral readouts to image the entire brain volume, often with a much smaller region of interest within the brain monitored for feedback purposes. Given that such brain activity should be sampled rapidly, it is worthwhile considering alternative functional magnetic resonance imaging pulse sequences that trade spatial resolution for temporal resolution. We developed a prototype sequence localizing a column of magnetization by outer volume saturation, from which densely sampled transverse relaxation time decays are obtained at coarse voxel locations using an asymmetric gradient echo train. For 5×20×20 mm3 voxels, 256 echoes are sampled at ~1 msec and then combined in weighted summation to increase functional magnetic resonance imaging signal contrast. This multiecho coarse voxel pulse sequence is shown experimentally at 1.5 T to provide the same signal contrast to noise ratio as obtained by spiral imaging for a primary motor cortex region of interest, but with potential for enhanced temporal resolution. A neurofeedback experiment also illustrates measurement and calculation of functional magnetic resonance imaging signals within 1 sec, emphasizing the future potential of the approach.

Magn Reson Med. 2011 Mar;65(3):715-24. doi: 10.1002/mrm.22674. Epub 2010 Nov 3. Kuo AY, Chiew M, Tam F, Cunningham C, Graham SJ. Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.

TrackBacks
There are no trackbacks for this entry.

Trackback URL for this entry:
http://www.hypnosisresearchinstitute.org/trackback.cfm?8FCBFDB2-9292-7039-350D114BD2C06D18

Comments
© 2000 - 2012The International Hypnosis Research Institute, All Rights Reserved.

Contact