Tim Brunson DCH

Welcome to The International Hypnosis Research Institute Web site. Our intention is to provide quality information to clinicians and the general public concerning hypnosis, hypnotherapy, and other mind/body modalities. We intend to expand our coverage to include such topics as Neuro-Linguistic Programming (NLP), energy psychology and medicine, and other related topics. While our intention is to provide quality information derived from valid sources, including peer reviewed literature concerning significant research, this site is not presented as a source of medical or psychological advice. Clinicians wishing to expand their scope of practice or protocols based upon presented information should perform due diligence prior to use. It is our sincere hope to stimulate interest in these topics and to contribute to the evolution of the science of hypnosis. -- Tim Brunson, PhD

Discrimination accuracy between real and sham needles using the Park sham device...

Full title: Discrimination accuracy between real and sham needles using the Park sham device in the upper and lower limbs.

OBJECTIVE: To evaluate the blinding effectiveness of the Park sham acupuncture device using participants' ability to discriminate between the real and sham acupuncture needles in the (1) upper limb (TE points) compared with pure guessing and (2) lower limb (BL points) compared with pure guessing. METHODS: 20 healthy acupuncture-naïve university students and staff were recruited through convenience sampling. Participants made Yes-No judgements on whether the real or sham needle was administered to four TE acupoints on the dominant upper limb, and four acupoints along the BL meridian on the dominant lower limb. The proportion of correct judgements, P(C), for each participant was calculated to indicate the discrimination accuracy of participants in distinguishing between the real and sham needles. Separate P(C) were computed for the upper limb acupoints and lower limb acupoints. The data were also pooled to calculate a P(C) for a combination of both body regions. RESULTS: The participants' discrimination accuracy between the real and sham needles was not statistically significant from P(C)=0.5 (chance level) for the lower limb alone and combined body regions' acupoint comparisons (lower limb: t(19)=0.00, unadjusted p=1.00; combined: t(19)=1.75, unadjusted p=0.10). However, the participants' discrimination accuracy was statistically significant from P(C)=0.5 for the upper limb acupoints alone comparison (t(19)=2.36, unadjusted p=0.03). CONCLUSIONS: This study showed that the Park sham device is more likely to blind participants in differentiating between the real and sham needles in the lower limb (BL meridian) acupoints than in the upper limb (TE meridian). However, the participants' ability to differentiate between the needle types for the upper limb acupoints was significantly different from chance levels.

Acupunct Med. 2011 Jun 7. Tan CW, Sheehan P, Santos D. School of Health Sciences, Queen Margaret University Edinburgh, Edinburgh, UK.

TrackBacks
There are no trackbacks for this entry.

Trackback URL for this entry:
http://www.hypnosisresearchinstitute.org/trackback.cfm?8F707B9C-05AF-197C-D7AF07BB646565A0

Comments
© 2000 - 2012The International Hypnosis Research Institute, All Rights Reserved.

Contact