Welcome to The International Hypnosis Research Institute Web site. Our intention is to provide quality information to clinicians and the general public concerning hypnosis, hypnotherapy, and other mind/body modalities. We intend to expand our coverage to include such topics as Neuro-Linguistic Programming (NLP), energy psychology and medicine, and other related topics. While our intention is to provide quality information derived from valid sources, including peer reviewed literature concerning significant research, this site is not presented as a source of medical or psychological advice. Clinicians wishing to expand their scope of practice or protocols based upon presented information should perform due diligence prior to use. It is our sincere hope to stimulate interest in these topics and to contribute to the evolution of the science of hypnosis. -- Tim Brunson DCH

Muscle and eye movement artifact removal prior to EEG source localization.

Muscle and eye movement artifacts are very prominent in the ictal EEG of patients suffering from epilepsy, thus making the dipole localization of ictal activity very unreliable. Recently, two techniques (BSS-CCA and pSVD) were developed to remove those artifacts. The purpose of this study is to assess whether the removal of muscle and eye movement artifacts improves the EEG dipole source localization. We used a total of 8 EEG fragments, each from another patient, first unfiltered, then filtered by the BSS-CCA and pSVD. In both the filtered and unfiltered EEG fragments we estimated multiple dipoles using RAP-MUSIC. The resulting dipoles were subjected to a K-means clustering algorithm, to extract the most prominent cluster. We found that the removal of muscle and eye artifact results to tighter and more clear dipole clusters. Furthermore, we found that localization of the filtered EEG corresponded with the localization derived from the ictal SPECT in 7 of the 8 patients. Therefore, we can conclude that the BSS-CCA and pSVD improve localization of ictal activity, thus making the localization more reliable for the presurgical evaluation of the patient.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:1002-5. Hallez H, Vergult A, Phlypo R, Van Hese P, De Clercq W, D'Asseler Y, Van de Walle R, Vanrumste B, Van Paesschen W, Van Huffel S, Lemahieu I. Dept. of Electron. & Inf. Syst., Ghent Univ.

TrackBacks
There are no trackbacks for this entry.

Trackback URL for this entry:
http://www.hypnosisresearchinstitute.org/trackback.cfm?010B09BA-C09F-2A3B-F6511CA3FA6839DE

Comments
© 2000 - 2008The International Hypnosis Research Institute, All Rights Reserved.

Contact