Welcome to The International Hypnosis Research Institute Web site. Our intention is to provide quality information to clinicians and the general public concerning hypnosis, hypnotherapy, and other mind/body modalities. We intend to expand our coverage to include such topics as Neuro-Linguistic Programming (NLP), energy psychology and medicine, and other related topics. While our intention is to provide quality information derived from valid sources, including peer reviewed literature concerning significant research, this site is not presented as a source of medical or psychological advice. Clinicians wishing to expand their scope of practice or protocols based upon presented information should perform due diligence prior to use. It is our sincere hope to stimulate interest in these topics and to contribute to the evolution of the science of hypnosis. -- Tim Brunson DCH

Hypnotic Depth During Hypnosis for Anaesthesia

To study the effects of S-ketamine on the EEG and to investigate whether spectral entropy of the EEG can be used to assess the depth of hypnosis during S-ketamine anesthesia. METHODS: The effects of sub-anesthetic (159 (21); mean (SD) ng/ml) and anesthetic (1,959 (442) ng/ml) serum concentrations of S-ketamine on state entropy (SE), response entropy (RE) and classical EEG spectral power variables (recorded using the Entropy Module, GE Healthcare, Helsinki, Finland) were studied in 8 healthy males. These EEG data were compared with EEG recordings from 6 matching subjects anesthetized with propofol. RESULTS: The entropy values decreased from the baseline SE 85 (3) and RE 96 (3) to SE 55 (18) and RE 72 (17) during S-ketamine anesthesia but both inter- and intra-individual variation of entropy indices was wide and their specificity to indicate unconsciousness was poor. Propofol induced more pronounced increase in delta power (P<0.02) than S-ketamine, whereas anesthetic S-ketamine induced more high frequency EEG activity in the gamma band (P<0.001). Relative power of 20-70 Hz EEG activity was associated with high SE (P=0.02) and RE (P=0.03) values during S-ketamine anesthesia. CONCLUSIONS: These differences in low and high frequency EEG power bands probably explain why entropy monitor, while adequate for propofol, is not suitable for assessing the depth of S-ketamine anesthesia. SIGNIFICANCE: The entropy monitor is not adequate for monitoring S-ketamine-induced hypnosis.

Turku PET Centre, University of Turku, P.O. Box 52, FIN-20521 Turku, Finland. anu.maksimow@utu.fi

TrackBacks
There are no trackbacks for this entry.

Trackback URL for this entry:
http://www.hypnosisresearchinstitute.org/trackback.cfm?AFA9D53A-C09F-2A3B-F61794028BEF5957

Comments
© 2000 - 2008The International Hypnosis Research Institute, All Rights Reserved.

Contact