Tim Brunson DCH

Welcome to The International Hypnosis Research Institute Web site. Our intention is to provide quality information to clinicians and the general public concerning hypnosis, hypnotherapy, and other mind/body modalities. We intend to expand our coverage to include such topics as Neuro-Linguistic Programming (NLP), energy psychology and medicine, and other related topics. While our intention is to provide quality information derived from valid sources, including peer reviewed literature concerning significant research, this site is not presented as a source of medical or psychological advice. Clinicians wishing to expand their scope of practice or protocols based upon presented information should perform due diligence prior to use. It is our sincere hope to stimulate interest in these topics and to contribute to the evolution of the science of hypnosis. -- Tim Brunson, PhD

Hynosis Compared to Sedation During Angioplasty

Forty-six patients were randomized to receive drug (group 1) or hypnotic sedation (group 2) during balloon angioplasty of the left anterior descending coronary artery. Patients were continuously monitored by intracoronary and standard electrocardiograms, and heart rate spectral variability was also recorded.

Normalized units of low- and high-frequency components and the ratio of low to high frequency were measured during balloon inflations. The ST segment shifted at the first balloon inflation from 0.02 +/- 0.01 to 0.09 +/- 0.6 mm in group 1 and from 0.02 +/- 0.08 to 0.1 +/- 0.6 in group 2 mm (p <0.05).

In group 1, the low-frequency band and the ratio of low to high frequency increased significantly during the first balloon inflation (from 59 +/- 10 to 75 +/- 10 normalized units and from 2.4 +/- 1.4 to 7.3 +/- 4.7, respectively; p <0.001). The increase of the ratio of low to high frequency was significantly related to ST shift (r = 0.706; p <0.01).

In contrast, no significant variation of spectral parameters was found in group 2. The increase in cardiac sympathetic activity associated with balloon inflation and myocardial ischemia during percutaneous transluminal coronary angioplasty of the left anterior descending coronary artery was selectively eliminated by hypnosis but not by drug sedation.

Citation: Baglini R, Sesana M, Capuano C, Gnecchi-Ruscone T, Ugo L, Danzi GB. Effect of hypnotic sedation during percutaneous transluminal coronary angioplasty on myocardial ischemia and cardiac sympathetic drive. Am J Cardiol. 2004 Apr 15;93(8):1035-8. robagl@katamail.com

TrackBacks
There are no trackbacks for this entry.

Trackback URL for this entry:
http://www.hypnosisresearchinstitute.org/trackback.cfm?A54BB982-C09F-2A3B-F6C76ADC81EB33E8

Comments
© 2000 - 2012The International Hypnosis Research Institute, All Rights Reserved.

Contact